National Instruments Introduces High-Performance PXI Express Data Acquisition With Integrated Signal Conditioning

Author
SySAdmin
Posted
May 25, 2010
Views
1683

Page All:

Page 1
National Instruments Introduces High-Performance PXI Express Data Acquisition With Integrated Signal Conditioning

Strain, Thermocouple and High-Voltage Analog Input Modules Offer Increased Accuracy for High-Channel-Count Measurement Systems

AUSTIN, Texas, May 25, 2010 -- National Instruments (NASDAQ:NATI) today announced the company's first data acquisition (DAQ) modules with integrated signal conditioning for scalable, high-performance measurements on PXI Express. The new NI SC Express family delivers increased accuracy, high data throughput and best-in-class synchronization for measuring strain gauges, bridge-based transducers, thermocouples and high-voltage analog inputs. PXI Express provides 250 MB/s of dedicated bandwidth for each SC Express module in the chassis, which helps engineers increase channel count without compromising sampling rates or data throughput. With a smaller footprint, simplified cable management and new software features for automatic synchronization, the SC Express modules make it easy for engineers to set up and program high-channel-count sensor measurement systems.

The NI PXIe-4330 24-bit simultaneous bridge input module offers 0.02 percent accuracy and 25 kS/s per channel sample rate for high-performance strain, load, force and torque measurements. The bridge input module achieves high accuracy with a ratiometric design where the ADC references the excitation voltage. This approach removes the measurement's dependence on the stability and accuracy of the excitation voltage. In addition, unique delta-sigma ADCs provide both excellent AC performance as well as DC accuracy, while traditional delta-sigma ADCs only offer AC performance.

The NI PXIe-4330 bridge input module can perform quarter, half and full bridge-based measurements with automatic synchronization features. The included driver software ensures tight synchronization across multiple modules and chassis with inter-channel skews as low as 5 ppb. The 8-channel bridge input module can scale to a 136-channel system in a single chassis and thousands of channels when synchronizing across multiple chassis. The high-accuracy, simultaneity and synchronization features make the NI PXIe-4330 module ideal for high-channel-count structural test applications, such as wind tunnels, bridge monitoring and crash tests.

With the NI PXIe-4353 thermocouple module, engineers can measure temperatures with 0.30 degrees C accuracy on 32 channels. The isothermal terminal block minimizes error with a unique design that optimizes thermal conductivity, making it possible for the nearby cold-junction compensation (CJC) thermistors to accurately measure at the thermocouple junctions. The 32-channel thermocouple module can scale to a 544-channel system in a single chassis and thousands of channels when synchronizing across multiple chassis. The increased accuracy and scalable platform make the NI PXIe-4353 module well-suited for precision measurements from a single channel to large systems for applications such as fuel cell testing and monitoring thermal chambers.

The NI PXIe-4300 high-voltage isolated analog input module is the first analog input module from National Instruments that can measure up to 300 V with simultaneous sampling. With a 16-bit ADC per channel and a 250 kS/s per channel sampling rate, the NI PXIe-4300 module can stream 4 MB/s per module and 68 MB/s in a single chassis. This 8-channel analog input module can scale to a 136-channel system in a single chassis and thousands of channels when synchronizing across multiple chassis. The ability to measure 300 V with CAT II channel-to-channel isolation makes the NI PXIe-4300 module ideal for automotive testing, such as fuel cell and battery tests.

The new SC Express modules include NI-DAQmx driver software and support for multi-device tasks, a new feature of NI-DAQmx that helps engineers easily synchronize multiple modules. The same code that acquires data from one module can synchronize up to 17 modules in a chassis. The modules work with a variety of NI hardware including NI X Series, dynamic signal acquisition (DSA) and NI SCXI products, and more than 1,500 types of I/O available on the PXI platform. The new modules also integrate with NI software including NI LabVIEW and the LabVIEW Real-Time Module, NI-Sync and NI DIAdem.

Readers can visit http://www.ni.com/lp/sc-express.htm to learn more about achieving higher measurement performance with the SC Express family.

About PXI

PCI eXtensions for Instrumentation (PXI) is an open specification governed by the PXI Systems Alliance (http://www.pxisa.org) that defines a rugged, CompactPCI-based platform optimized for test, measurement and control. Founded in 1997, the PXI specification is supported by more than 70 vendors offering more than 1,500 PXI products. PXI products are compatible with the CompactPCI and CompactPCI Express industrial computer standards and offer additional features such as environmental specifications, standardized software and built-in timing and synchronization.

About National Instruments

National Instruments (http://www.ni.com) is transforming the way engineers and scientists design, prototype and deploy systems for measurement, automation and embedded applications. NI empowers customers with off-the-shelf software such as NI LabVIEW and modular cost-effective hardware, and sells to a broad base of more than 30,000 different companies worldwide, with no one customer representing more than 3 percent of revenue and no one industry representing more than 15 percent of revenue. Headquartered in Austin, Texas, NI has more than 5,000 employees and direct operations in more than 40 countries. For the past 11 years, FORTUNE magazine has named NI one of the 100 best companies to work for in America. Readers can obtain investment information from the company's investor relations department by calling (512) 683-5090, e-mailing nati@ni.com or visiting http://www.ni.com/nati.

  Pricing and Contact Information
                                     11500 N Mopac Expwy, Austin, Texas
  NI PXIe-4330                       78759-3504
  Priced* from $2,799; euro 2,699;
   350,000 yen                      Tel: (800) 258-7022, Fax: (512) 683-9300
  NI PXIe-4353                      E-mail: info@ni.com
  Priced* from $1,899; euro 1,849;
   238,000 yen
  NI PXIe-4300
  Priced* from $1,899; euro 1,849;
   238,000 yen
  Web: http://www.ni.com/lp/sc-express.htm
  *Prices are subject to change
   without notice.

DIAdem, LabVIEW, National Instruments, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.

Editor Contact:    Hilary Marchbanks, (512) 683-5937

Reader Contact:    Ernest Martinez, (800) 258-7022

Photo:  http://www.newscom.com/cgi-bin/prnh/20080723/LAW030LOGO
AP Archive: http://photoarchive.ap.org/
PRN Photo Desk, photodesk@prnewswire.com
Source: National Instruments
   

CONTACT:  Editors, Hilary Marchbanks, +1-512-683-5937, or Readers, Ernest
Martinez, 1-800-258-7022, both of National Instruments

Web Site:  http://www.ni.com/

Title

Medium Image View Large